Login|Register|Forget password|Dashboard Back to Home|Contact|Shopcart
Unverified1st Year

Ningbo Hyuan Power Industry Co., Ltd.  

Search
新闻中心
  • 暂无新闻
产品分类
  • 暂无分类
联系方式
  • 联系人:Tailichen
  • 电话:86-574-88079270
  • 传真:86-574-88079270
站内搜索
 
荣誉资质
  • 暂未上传
友情链接
  • 暂无链接
首页 > Products > 15kv/27kv/38kv Recloser Wtith IEC61850 and DNP3.0 for Distribution and Substation
15kv/27kv/38kv Recloser Wtith IEC61850 and DNP3.0 for Distribution and Substation
单价 $3.00 / Piece对比
询价 暂无
浏览 254
发货 Chinazhejiangningbo
库存 5000Piece
过期 长期有效
更新 2020-04-22 12:33
 
详细信息
Product Name: 15kv/27kv/38kv Recloser Wtith IEC61850 and DNP3.0 for Distribution and Substation Model NO.: CHZ4 Installation Type: Pole Mounted /Substation Mounted Comunication Port: RS232, RS485, RJ45, WiFi, Blueteeth, GPRS Protocol: IEC61850, IEC104.IEC101, DNP3.0, Modbus Standard: IEC/IEEE/ANSI/GB Trademark: HEMG Transport Package: Wooden/Carton Specification: 15KV/27KV/38KV, 50HZ/60HZ, 630A/1250A Origin: China Product Description 1.0 InstructionThe CHZ4(T)-12(15/27/38) KV/630A-1250A Providing the features of a traditional re-closer, plus the bene of up to date design optimized for automation, remote control and monitoring, now or in the future.by customer demand for improved return on capital investment in the distribution network to achieve optimum performance and reliability, making use of the latest available technology in insulation, vacuum interruption and microelectronics.Three phase pole-top automatic circuit re-closer are designed and produced by the three kind of international advanced technology, as epoxy solid encapsulated technology, permanent magnetic actuating device, and intelligence control technology and so on.The product is composite with solid dielectric insulted pole, permanent magnetic actuating device or motor actuating device, control unit, current transformer and vacuum interrupter and voltage sensor. Except the control unit is a single device, the others are combined together, compact frame, flexible design, easy to operate.The CHZ4(T)-12(15/27/38) KV/630A-1250A three phase pole-top automatic circuit re-closer is for 12kV(15KV/27KV/38KV),50/60Hz distribution system, has not only circuit breaker control and protection features, but also can automatically detect the lines running statement.once the load side line or equipment occur a fault, meet or exceed current setting the minimum starting current, it will be good at a per-determined action sequence, to identify the fault is transient or permanent, and auto-complete one to three re-closing.2.0 Designing Standard2.0.1 ANSI-IEEE-Std-C37.60-2003,2.0.2 BS EN 60529-1992+A2:20132.0.3 IEEE Std.C37.60-2013, IEEE Std C57.12.29-20142.0.4 JB7570-1994, and DL/T813-20022.0.5 IEC56, IEC694, IEC62271-1113.Specification for Vacuum Circuit Breaker 3.1 Ratings for ZW32-12(15) KV Vacuum Circuit BreakerNo.ItemUnitData for ZW32-12KVData for ZW32-15KV1Rated VoltageKV12152Rated insulation level(phase to ground, phase to phase)1 min Frequency withstand voltageDryKV4250Wet3445Lighting Impulse Withstand Voltage(Peak)KV751103Medium Interruption:Vacuum4Medium isolation:Solid polymer5Mechanism of operation (closing and shot):Magnetic6Assembly:Suitable weather for substation7Environmental operating temperature:FROM -40ºC-+50ºC8Position indicator: Green-closed; Open-red9Minimum distance of contouring of the insulationMM40060010Rated FrequencyHz50/6011Rated CurrentA630/800/125012Rated Min Start-up CurrentNumericalAadjustablePermissible deviation%±1013Rated Fault Interrupter CapacityKA/3s12.5/2014Rated Fault Symmetrical Making CurrentKA12.5/2015Rated Short-Time Withstand CurrentKA12.5/2016Rated Peak Withstand CurrentKA12.5/2017Interrupting Time(Max) (Cycle)sNo more than 418The conditions of different phase earthed fault short-circuit breaking currentKA17.319Rated Cable Charging Breaking currentA2520Rated Operating SequenceO-0.1s-CO-2s-CO-2s-CO-C21Rated Operation VoltageVAC/DC110/125/220/24022Rated Short-Circuit Current Breaking TimesTime90%~100% Rated Short-Circuit Current volume1645%~55% Rated Short-Circuit Current volume4415%~20% Rated Short-Circuit Current volume5623Mechanical Life (Mechanical stability)Time/Unit Operation1500024Current TransformerPrimary Rated CurrentA600/1000Secondary Rated Current1 or 5Accuracy GradeCL0.2/5P20CapabilityVA1525Special Manual Closing Mechanismoptional26EarthingSolidly Earthed3.2 Ratings for ZW32-27(38) KV Vacuum Circuit BreakerNo.ItemUnitData for ZW32-27KVData for ZW32-38KV1Rated VoltageKV27382Rated insulation level (phase to ground, phase to phase)1 min Frequency withstand voltageDryKV6595Wet5080Lighting Impulse Withstand Voltage(Peak)KV145/1501853Medium Interruption:Vacuum4Medium isolation:Solid polymer5Mechanism of operation (closing and shot):Magnetic6Assembly:Suitable outdoor for substation or pole mounted7Environmental operating temperature:FROM -40ºC-+50ºC8Position indicator: Green-closed; Open-red9Minimum distance of contouring of the insulationMM68090010Rated FrequencyHz50/6011Rated CurrentA200A/400A/630A/1250A12Rated Min Start-up CurrentNumericalAAdjustablePermissible deviation%±1013Rated Fault Interrupting CapacityKA/3S12.5/2014Rated Symmetrical Making CurrentKA12.5/2015Rated Short-Time Withstand CurrentKA12.5/2016Rated Peak Withstand CurrentKA12.5/2017Interrupting time(Max)(Cycle)SNot more than 418The conditions of different phase earthed fault short-circuit breaking currentKA12.52019Rated Cable Charging Breaking currentA2520Rated Operating SequenceO-0.1s-CO-2s-CO-5s-CO-C21Rated Operation VoltageVAC/DC110/125/220/24022Rated Short-Circuit Current Breaking TimesTime90%~100% Rated Short-Circuit Current volume1645%~55% Rated Short-Circuit Current volume4415%~20% Rated Short-Circuit Current volume5623Mechanical Life (Mechanical stability)Time/unit Operation1000024Current TransformerPrimary Rated CurrentA600/1000Secondary Rated Current1 or 5Accuracy GradeCL0.25/5P20CapabilityVA1525Special Manual Closing MechanismOption26FarthingSolidly Earthed4.Intelligent Controller Communications CubicleThe product is supplied complete with an CHK4(T/S) series controller to achieve the various functions Including of measurement, protection, control and communication requirements. The controller can achieve the functions are as follows:CHK4 ConTROLS FUNCTIONS AND CHARACTERISTICS1.Control panel is operated by manual or PC2.Remote control is by through SCADA3.Total time maximum opening3 cycles/50ms for 60hz4.Re-close time and programming stepProgrammable5.Independent calibration groups, minimumAutomatic Protection Group Selection is used to change the protection, group depending on the direction of power flow. This allows the re-closer to be correctly graded with devices downstream regardless of the power flow direction.3/4each of which can be configuredwith completely separate protection characteristics with different inverse time curves and setting currents. The number of protection groups available to the operator can be configured, thereby restricting or enabling access to protection settings as required6Operation with dead line With battery bank if AC power is lost1.Back up battery bank power for 48hours without charging2.100times operation within 48hours3.Battery bank is charged by intelligent charger in controller cabinet from outside PT7.It is with Control and microprocessor protection8.Selection of number of operations fast0-4 from IEC curve9.Selection of number of slow operations0-4 from IEC curve10.Selection of number of lock operations1-4 IEC curve11.Buttons with indicators (LED's). Applicable control with microprocessor relay12.Modification of curves by time (dial) tap in current and adding time-definiteFOR IEC 5 Curve and IEEE 3 curve13.Minimum programmable LED's. It applies to control with microprocessor relay.4 (u)14.Automatic Re-closer locking15.Remote operation lock16.Levels of access codes to configuration17.Fault recorder18.FOR PROTECTION CURRENT TRANSFORMERS:18.1Relation For Phases1000/600/400/200/100:1/518.1.1Precision for protection:+/- 5%18.1.2Material of the bushingsPolymer18.2Relation for Ground200/100/50:1/5(POTION)18.2.1Precision for protection5P18.2.2Material of the bushingPolymer19.FEATURES OF THE ELECTRonIC CONTROL19.1Type of installation:Outdoor for mounting substation or pole19.2Degree of protection:IP65/IP5419.3AccessFront19.4Memory type:Non-volatile20.THE ConTROL UNIT SHOULD INCLUDE:20.1Liquid crystal displayLCD(3"x1"/77mmx27mm)20.2Membrane keyboard20.3LED's for indication of the State of the control, Re-closer (open/close) and the shooting conditions21.OPERATION BUTTONS TO ENABLE / DISABLE THE FOLLOWING FUNCTIONS:21.1Ground-fault trip21.2Automatic Re-closer21.3Remote control21.4Buttons for closure and manual (local) tripping of the unit21.5Function of hot line tag to configurable buttons for change of setting and activation of control logic or blocking local group.22PROTECTION FUNCTIONS22.1Instantaneous over current for phase, neutral and negative sequence50 relays PGQ/50N22.2Timed over current for phase, neutral and negative sequence51 relays PGQ/51N22.3Sequence ComponentsNegative, positive and zero phase sequence currents and voltages can bemonitored and logged.In addition, the negative phase sequence current protection can be used fordetection of low-level phase-to-phase faults in the presence of high level three phaseloads. Inverse Time, Definite Time and Instantaneous operation is available.Setting current range: 10 - 1260 A22.4Sequence CoordinationSequence Coordination allows a recloser to coordinate it's trip sequence withanother recloser downstream22.5Auto-re-closerRelay 79 (sequence 1,2,3,4)Operating SequenceReclose times are individually selectable. The operating sequence is defined by:O - 1st rt - CO - 2nd rt - CO - 3rd rt - COwhere rt = reclose time.where O = open.where C = close.1st Reclose Time range: 0.2 - 180 sec2nd Reclose Time range: 2.0 - 180 sec3rd Reclose Time range: 2.0 - 180 secTiming resolution: 0.1 secRecovery/ Reset Time: 0.1 - 180 secSequence Reset Timing resolution: 1 sec22.6Trips to LockoutOvercurrent and fault trips to lockout are selectable between 1 and 4. A separatesetting is available for Sensitive Earth Fault and Negative Phase Sequence.22.7Loss of phaseLoss of phase protection trips the re-closer if phase-earth voltage on one or two, phases falls below a set voltage threshold for a set length of time.Threshold voltage range: 2 - 15kVVoltage resolution: 1VTime range: 0.1 - 100 secTime resolution: 0.1 sec22.8Live load blockingLive load blocking prevents a re-closer from closing if any of the load side terminalsare live.Live Load Threshold Voltage range: 2 - 15kV22.9Dead lockoutDead lockout prevents a reclose unless one or more of the source side or load sideterminals are live. If all terminals are dead, then the controller goes to lockout22.10Envelope and low frequencyThis feature trips the re-closer when the system frequency exceeds the under andover frequency trip threshold values. Frequency tripping range: 45 - 65 HzRelay 81Frequency calculation: once per cycle over a two-cycle periodNumber of under/over frequency cycles before tripping: 2 - 1000Accuracy: ±0.05Hz22.11Over voltageRelay 5922.12Low voltageRelay 2722.13DistanceRelay 2122.14Directional blockingDirectional protection67 relay PGQ/67Na protection feature that restricts tripping on faults to adesignated side of the re-closer. It prevents nuisance tripping if networkconditions are causing "false" earth faults. In radial systems, Directional Blockingprevents nuisance tripping by blocking faults in the source direction and only responding to faults in the load direction.Distinct protection for faults in the forward and reverse direction. A forward fault mayuse a different time-current curve and settings to a reverse fault (i.e. these areindividually selectable). Both the forward protection and reverse protection areoperating at the same time. This is an additional protection feature22.15Cold load picks up(OPTIONAL)Cold load pick-up allows for a loss of diversity when a load has been without supplyfor a period.Multiplier range: 1 - 5Multiplier resolution: 0.1Time Constant range: 1 - 480 minTime constant resolution: 1 min22.16High impedance/conductor broken failureOptional22.17harmonicoptional22.18Protection time-current curves:1. IEC/IEEE ,2.ANSI(OPETIONAL)3.(optional Non Standard Inverse Time Curves)IEC 60255 CURVESInverse,Very Inverse and Extremely Inverse.IEEE C37.122Moderately Inverse,Very Inverse and Extremely Inverse.22.19Instantaneous protectionInstantaneous protection works by tripping the re-closer if the line current exceedsthe Instantaneous Multiplier x Setting Current.Multiplier range: 1 - 30Resolution of setting: 0.1Max effective setting: 12.5kA22.20Definite time protectionDefinite Time is an alternative to Inverse Time protection. It works by tripping theRe-closer at a fixed time after pick-up.Setting current range: 10 - 1260ADefinite time resolution: 0.1 secDefinite time range: 0.01 - 100 secSetting current resolution: 1A22.21Sensitive Earth Fault (SEF)SEF trip Current Range: 5A-25AMIN 5A(to Ground)/MIN25A(to phases)SEF operating time range: 0.1-999secSEF trip current setting resolution: 1ASEF operating time resolution: 0.1S22.22Under / Over Voltage ProtectionWhen selected, and a nominal Phase to Earth System operating voltage is set, the UOV Protection works within a defined threshold above and below the specifiedvoltage.Under Voltage Lower Threshold Range:50% - 88%Over Voltage Upper Threshold Range: 112% - 150%Trip After X Secs Range: 0 - 300 SecondsPhase Logic1.When ALL phases deviate beyond thresholds2.When ANY phase voltage deviates beyond the thresholds3.When the numerical AVERAGE of all phase Voltages deviates beyond the threshold.22.23Inrush restraintInrush restraint raises the phase and earth threshold currents for a short period oftime to allow for short duration inrush currents when closing onto a load.Multiplier range: 1 - 30Multiplier resolution: 0.1Time range: 0.05 - 30 secTime resolution: 0.05 sec23MEASUREMENT FUNCTIONS23.1VoltageBy phase,line and neutral23.2Current (0-1250A)By phase ,line and neutral23.3Power (Active and reactive)By phase and line23.4Energy (Active and reactive)By phase and line23.5Power factorBy phase and line22.6Load profile registry (Amperage, voltage, power,energy power factor)1.registry Every 15 minutes2.Optional adjustable (0-60MIN)24ADDITIonAL FUNCTIONS:24.1Events Registrar1.216 records of events2.216 records of remote control3.216 records of events of failure4.45 records for fault waveform(15before and 30 after)5.216 records of history events24.2The battery status monitor24.3Inputs and outputs programmable by the user24.4Native protocol Mod-bus/DNP3.0 profile25COMMUNICATION PORTS:25.1RS232 for Setting of communication protocols and Maintain of the control by PC25.2RJ45 for Setting, Program and Receiving of control BY PC25.3RS-232 for communicationWith DNP 3.0 /Mod-bus interface25.4RS-485 for communicationWith DNP 3.0 /Mod-bus interface25.5RJ45 for remote communicationWith DNP 3.0/IEC61850 standard interface25.6GRPS or Bluetooth or WI-FI or radio to connect with laptop25.7Unit with 1 or 2 Fiber optic port and 3 RJ45 Ethernet communication (option)25.8Protocol IEC60870-5-104/IEC69870-5-101 /DNP3.0/MODBUS/IEC61850(option)25.9COMMUNICATION BETWEEN RELAYS(OPTIONAL)26Supply voltage:110/125/220/220VAC/DC(OPTIONAL)27Frequency:50Hz/60 Hz(OPTIONAL)28Back-up batteries: sealed free maintance ,rechargeable in control box ,monitor of power on diagnostic and continuous self monitoring1.2AH/7AH/17AH/24AH(OPTIONAL)2.2x12V=24VDC or 4x12v=48VDC3.48hours with 20w if loss of power29Life years of recloser10yearsLife years of battery5 years30Integrated battery charger/monitor is included3112VDC integrated auxiliary output to power a radio or moden another device for remote or local data transmission32Included of Heating resistors33Included of Control cable 15M and power cable from PT (option)34Included of Setting ,Programming and Receiving software35Including of ac lamps and heaters of moisture contol36Including of electricnic magnetic lock for control box37Microprocessor realy in the front will be with IP20 to avoid of dust ,insert ,air contaminats ,high humidity and vibration.38Main Protection Function Schematic