详细信息 Product Name: Recloser Control with IEC61850/DNP3.0/IEC104/IEC101/Modbus/Blueteeth/Wireless Model NO.: CHK4 Battery Type: AAA Battery Material: Stainless 2.0mm Voltage: 3V Transmission Distance: >100m Universal: Universal Certification: ISO9001, CE Type: DNP/IEC61850 Signal Transmission: RF Remote Control Application: Distribution Automation Trademark: HEMG Transport Package: Carton with Wooden Specification: WITH PROTECTION AND COMMUNICATION Origin: China Product Description CHK4 ConTROL FOR 15/27/38KVAutomatic Circuit Re-closer1.0 Designing Standard2.0.1 ANSI-IEEE-Std-C37.60-2003,2.0.2 BS EN 60529-1992+A2:20132.0.3 IEEE Std.C37.60-2013, IEEE Std C57.12.29-20142.0.4 JB7570-1994, and DL/T813-20022.0.5 IEC56, IEC694, IEC62271-1112.Intelligent Controller Communications CubicleThe product is supplied complete with an CHK4(T/S) series controller to achieve the various functions Including of measurement, protection, control and communication requirements. The controller can achieve the functions are as follows:CHK4 ConTROLS FUNCTIONS AND CHARACTERISTICS1.Control panel is operated by manual or PC2.Remote control is by through SCADA3.Total time maximum opening3 cycles/50ms for 60hz4.Re-close time and programming stepProgrammable5.Independent calibration groups, minimumAutomatic Protection Group Selection is used to change the protection, group depending on the direction of power flow. This allows the re-closer to be correctly graded with devices downstream regardless of the power flow direction.3/4each of which can be configuredwith completely separate protection characteristics with different inverse time curves and setting currents. The number of protection groups available to the operator can be configured, thereby restricting or enabling access to protection settings as required6Operation with dead line With battery bank if AC power is lostBack up battery bank power for 48hours without charging 100times operation within 48hoursBattery bank is charged by intelligent charger in controller cabinet from outside PT7.It is with Control and microprocessor protection8.Selection of number of operations fast0-4 from IEC curve9.Selection of number of slow operations0-4 from IEC curve10.Selection of number of lock operations1-4 IEC curve11.Buttons with indicators (LED's). Applicable control with microprocessor relay12.Modification of curves by time (dial) tap in current and adding time-definiteFOR IEC 5 Curve and IEEE 3 curve13.Minimum programmable LED's. It applies to control with microprocessor relay.4 (u)14.Automatic Re-closer locking15.Remote operation lock16.Levels of access codes to configuration17.Fault recorder18.FOR PROTECTION CURRENT TRANSFORMERS:18.1Relation For Phases1000/600/400/200/100:1/518.1.1Precision for protection:+/- 5%18.1.2Material of the bushingsPolymer18.2Relation for Ground200/100/50:1/5(POTION)18.2.1Precision for protection5P18.2.2Material of the bushingPolymer19.FEATURES OF THE ELECTRonIC CONTROL19.1Type of installation:Outdoor for mounting substation or pole19.2Degree of protection:IP65/IP5419.3AccessFront19.4Memory type:Non-volatile20.THE ConTROL UNIT SHOULD INCLUDE:20.1Liquid crystal displayLCD(3"x1"/77mmx27mm)20.2Membrane keyboard20.3LED's for indication of the State of the control, Re-closer (open/close) and the shooting conditions21.OPERATION BUTTONS TO ENABLE / DISABLE THE FOLLOWING FUNCTIONS:21.1Ground-fault trip21.2Automatic Re-closer21.3Remote control21.4Buttons for closure and manual (local) tripping of the unit21.5Function of hot line tag to configurable buttons for change of setting and activation of control logic or blocking local group.22PROTECTION FUNCTIONS22.1Instantaneous over current for phase, neutral and negative sequence50 relays PGQ/50N22.2Timed over current for phase, neutral and negative sequence51 relays PGQ/51N22.3Sequence ComponentsNegative, positive and zero phase sequence currents and voltages can bemonitored and logged.In addition, the negative phase sequence current protection can be used fordetection of low-level phase-to-phase faults in the presence of high level three phaseloads. Inverse Time, Definite Time and Instantaneous operation is available.Setting current range: 10 - 1260 A22.4Sequence CoordinationSequence Coordination allows a recloser to coordinate it's trip sequence withanother recloser downstream22.5Auto-re-closerRelay 79 (sequence 1,2,3,4)Operating SequenceReclose times are individually selectable. The operating sequence is defined by:O - 1st rt - CO - 2nd rt - CO - 3rd rt - COwhere rt = reclose time.where O = open.where C = close.1st Reclose Time range: 0.2 - 180 sec2nd Reclose Time range: 2.0 - 180 sec3rd Reclose Time range: 2.0 - 180 secTiming resolution: 0.1 secRecovery/ Reset Time: 0.1 - 180 secSequence Reset Timing resolution: 1 sec22.6Trips to LockoutOvercurrent and fault trips to lockout are selectable between 1 and 4. A separatesetting is available for Sensitive Earth Fault and Negative Phase Sequence.22.7Loss of phaseLoss of phase protection trips the re-closer if phase-earth voltage on one or two, phases falls below a set voltage threshold for a set length of time.Threshold voltage range: 2 - 15kVVoltage resolution: 1VTime range: 0.1 - 100 secTime resolution: 0.1 sec22.8Live load blockingLive load blocking prevents a re-closer from closing if any of the load side terminalsare live.Live Load Threshold Voltage range: 2 - 15kV22.9Dead lockoutDead lockout prevents a reclose unless one or more of the source side or load sideterminals are live. If all terminals are dead, then the controller goes to lockout22.10Envelope and low frequencyThis feature trips the re-closer when the system frequency exceeds the under andover frequency trip threshold values. Frequency tripping range: 45 - 65 HzRelay 81Frequency calculation: once per cycle over a two-cycle periodNumber of under/over frequency cycles before tripping: 2 - 1000Accuracy: ±0.05Hz22.11Over voltageRelay 5922.12Low voltageRelay 2722.13DistanceRelay 2122.14Directional blockingDirectional protection67 relay PGQ/67Na protection feature that restricts tripping on faults to adesignated side of the re-closer. It prevents nuisance tripping if networkconditions are causing "false" earth faults. In radial systems, Directional Blockingprevents nuisance tripping by blocking faults in the source direction and only responding to faults in the load direction.Distinct protection for faults in the forward and reverse direction. A forward fault mayuse a different time-current curve and settings to a reverse fault (i.e. these areindividually selectable). Both the forward protection and reverse protection areoperating at the same time. This is an additional protection feature22.15Cold load picks up(OPTIONAL)Cold load pick-up allows for a loss of diversity when a load has been without supplyfor a period.Multiplier range: 1 - 5Multiplier resolution: 0.1Time Constant range: 1 - 480 minTime constant resolution: 1 min22.16High impedance/conductor broken failureOptional22.17harmonicoptional22.18Protection time-current curves:1. IEC/IEEE ,2.ANSI(OPETIONAL)3.(optional Non Standard Inverse Time Curves)IEC 60255 CURVESInverse,Very Inverse and Extremely Inverse.IEEE C37.122Moderately Inverse,Very Inverse and Extremely Inverse.22.19Instantaneous protectionInstantaneous protection works by tripping the re-closer if the line current exceedsthe Instantaneous Multiplier x Setting Current.Multiplier range: 1 - 30Resolution of setting: 0.1Max effective setting: 12.5kA22.20Definite time protectionDefinite Time is an alternative to Inverse Time protection. It works by tripping theRe-closer at a fixed time after pick-up.Setting current range: 10 - 1260ADefinite time resolution: 0.1 secDefinite time range: 0.01 - 100 secSetting current resolution: 1A22.21Sensitive Earth Fault (SEF)SEF trip Current Range: 5A-25AMIN 5A(to Ground)/MIN25A(to phases)SEF operating time range: 0.1-999secSEF trip current setting resolution: 1ASEF operating time resolution: 0.1S22.22Under / Over Voltage ProtectionWhen selected, and a nominal Phase to Earth System operating voltage is set, the UOV Protection works within a defined threshold above and below the specifiedvoltage.Under Voltage Lower Threshold Range:50% - 88%Over Voltage Upper Threshold Range: 112% - 150%Trip After X Secs Range: 0 - 300 SecondsPhase Logic1.When ALL phases deviate beyond thresholds2.When ANY phase voltage deviates beyond the thresholds3.When the numerical AVERAGE of all phase Voltages deviates beyond the threshold.22.23Inrush restraintInrush restraint raises the phase and earth threshold currents for a short period oftime to allow for short duration inrush currents when closing onto a load.Multiplier range: 1 - 30Multiplier resolution: 0.1Time range: 0.05 - 30 secTime resolution: 0.05 sec23MEASUREMENT FUNCTIONS23.1VoltageBy phase,line and neutral23.2Current (0-1250A)By phase ,line and neutral23.3Power (Active and reactive)By phase and line23.4Energy (Active and reactive)By phase and line23.5Power factorBy phase and line22.6Load profile registry (Amperage, voltage, power,energy power factor)1.registry Every 15 minutes2.Optional adjustable (0-60MIN)24ADDITIonAL FUNCTIONS:24.1Events Registrar216 records of events 216 records of remote control216 records of events of failure 45 records for fault waveform(15before and 30 after)216 records of history events24.2The battery status monitor24.3Inputs and outputs programmable by the user24.4Native protocol Mod-bus/DNP3.0 profile25COMMUNICATION PORTS:25.1RS232 for Setting of communication protocols and Maintain of the control by PC25.2RJ45 for Setting, Program and Receiving of control BY PC25.3RS-232 for communicationWith DNP 3.0 /Mod-bus interface25.4RS-485 for communicationWith DNP 3.0 /Mod-bus interface25.5RJ45 for remote communicationWith DNP 3.0/IEC61850 standard interface25.6GRPS or Bluetooth or WI-FI or radio to connect with laptop25.7Unit with 1 or 2 Fiber optic port and 3 RJ45 Ethernet communication (option)25.8Protocol IEC60870-5-104/IEC60870-5-101 /DNP3.0/MODBUS/IEC61850(option)25.9COMMUNICATION BETWEEN RELAYS(OPTIONAL)26Supply voltage:110/125/220/220VAC/DC(OPTIONAL)27Frequency:50Hz/60 Hz(OPTIONAL)28Back-up batteries: sealed free maintance ,rechargeable in control box ,monitor of power on diagnostic and continuous self monitoring1.2AH/7AH/17AH/24AH(OPTIONAL)2.2x12V=24VDC or 4x12v=48VDC3.48hours with 20w if loss of power29Life years of recloser10yearsLife years of battery5 years30Integrated battery charger/monitor is included3112VDC integrated auxiliary output to power a radio or moden another device for remote or local data transmission32Included of Heating resistors33Included of Control cable 15M and power cable from PT (option)34Included of Setting ,Programming and Receiving software35Including of ac lamps and heaters of moisture contol36Including of electricnic magnetic lock for control box37Microprocessor realy in the front will be with IP20 to avoid of dust ,insert ,air contaminats ,high humidity and vibration.38Main Protection Function SchematicMain protection function schematic diagram3. Automation and Communication3.1 The base model CHK4(T)(S) re-closer control is equipped with10/100base-T Ethernet port RJ45 Independently-operated RS-232 RS-485 serial ports. 100base-FX optical Ethernet ports optional USB port Wi-Fi Optional GPRS optional3.2 Serial CommunicationThe CHK4 retains all of the serial communications RS232, RS485 and USB PORT, Use any communications processor software that emulates a standard terminal system.3.3 Ethernet CommunicationUse the Ethernet ports RJ45 for local and remote engineering access, SCADA, real-time protection and control, loop restoration, islanding detection, blocking and fast bus tripping schemes, and firmware upgrades. High-speedEthernet ports are valuable for engineering access and control setup.3.4 Communications Protocol3.4.1 Ethernet network communication via RJ-45 or LC fiber optic connectors3.4.2 Serial communications via RS-232, RS-485, or ST fiber optic connection3.4.3 IEC 61850, with GOOSE messaging (standard)3.4.4 DNP 3.0 Level 23.4.5 IEC 60870-5-101/1043.4.6 Modbus RTU/ASCII3.4.7 The event generation subsystem provides consistent timestamping across all protocols3.4.8 Simultaneously report events to five IEC 61850 clients3.4.9 Time sync using IRIG-B, DNP, or SNTP3.4.10 Standard protocols: IEC61850+GOOSE+WebServer+SNTP+DNP3.0L2+Modbus
|