Login|Register|Forget password|Dashboard Back to Home|Contact|Shopcart
Unverified1st Year

Ningbo Hyuan Power Industry Co., Ltd.  

Search
新闻中心
  • 暂无新闻
产品分类
  • 暂无分类
联系方式
  • 联系人:Tailichen
  • 电话:86-574-88079270
  • 传真:86-574-88079270
站内搜索
 
荣誉资质
  • 暂未上传
友情链接
  • 暂无链接
首页 > Products > Protection and Control and Metering PCM Panel of Different Protion for Power Transformer up to 230kv
Protection and Control and Metering PCM Panel of Different Protion for Power Transformer up to 230kv
单价 $30.00 / Piece对比
询价 暂无
浏览 197
发货 Chinazhejiangningbo
库存 100000Piece
过期 长期有效
更新 2020-04-22 12:35
 
详细信息
Product Name: Protection and Control and Metering PCM Panel of Different Protion for Power Transformer up to 230kv Model NO.: PCM Frequency Characteristics: High Frequency Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer Certification: ISO9001-2000, ISO9001 Phase: Three Application: Power, Instrument Trademark: HEMG/ABB/SIMENS Transport Package: Carton with Wooden Specification: 33KV/72.5KV/123KV/132KV/145KV Origin: China Product Description No.DEscriptION TION UNID.VALUE REQUIRED VALUE OFFERED1.0.0GENERAL DATA 1.1.0Maker ABB/SAC1.2.0ModelRET6501.3.0Country of manufactureSweden/China2.0.0ConSTRUCTIVE ASPECTS 2.1.0FrequencyHz6050/60Hz2.2.0WeightKgIndicate3002.3.0Approximate Dimensions (Height, Width, Depth) (,,)MmIndicate2260*800*600mm(H*W*D)2.4.0Mounting YesYes2.5.0Operating temperature ° C-10 to +55-25 to +55ºC2.6.0Storage temperature° C-40 to +70-40 to +85ºC2.7.0Relative Humidity Range%10 to 90<93%3.0.0TENSION AND CURRENT ANALOGUE INPUTSNumber of analog inputs 24123.1.0Voltage inputs- Number of entriesReferring to Fig. - Rated voltage (Vn) Vac110110V - Operating marginVac0 - 340- Maximum permanent voltage Vac420420V rms- Maximum tension for 10 seconds Vac450450V rmsBurden GOES<.02 To 110Vac<0.05 VA3.2.0Current Inputs - Number of entries fifteen6- Rated current (In) (IN)Amp.11/5A- Operating margin Amp.(0-100) x In- Maximum permanent current Amp.4 In20A- Maximum current for 1 sec. Amp.100 In500ABurdenGOES<0.02 to 1A<0.05 VA 4.0.0DEPARTURES AND BINARY ENTRIES YesYes4.1.0Programmable Trip and Signaling Outputs - Number of contacts (minimum) -()No.2424- Maximum operating voltage -Vac/ Vdc250Vac, Vdc250Vac, Vdc- Test voltage at the open contact, for 1 min. -,1.Vrms1000Meet- Permanent current carrying capacity -TOReferring to Fig.5A- Current carrying capacity for 1 sec - 1sTO1010A (3s)10A (0.5s)- Cutting capacity TO110 V / 0.4 A48V / ≤0.5 A 110V / ≤0.1 A 220V / ≤0.04 A125V / 0.35A- Closing capacityTO30 A (for 0.2 s) 10 A (per 1.0 s)Meet4.2.0Inputs - Programmable input contacts YesYes- Number of input contacts (minimum) ()No.32Max.50- Voltage range V24 - 25024...250 V DC- Power consumption per input W0.2 W to 125 V<0.3 W4.3.0LED's of signaling YesYes- relay status 3Meet- the performance of the protection functions -15 (6 red and 9 yellow) 15(69)154.5.0Interfaces - Large HMI on the relay front panel HMIYesYes- Front Ethernet port, PC connection -,PC1 port, RJ451 port, RJ45- Ethernet optical port for remote communication 1 port, STMeet4.6.0Remote Communication - Communication protocol IEC 61850IEC 61850- Communication speed MBps100100 MBits/s5.0.0AUXILIARY SUPPLY 5.1.0Auxiliary Rated Voltage Vcc90 to 25088...300 V DC5.2.0Tolerance %± 20%15%5.3.0Typical Consumption - In normal operating condition -Wfifty30W5.4.0Auxiliary insertion power TO<5 A, for 0.1sec<5 A, for 0.1sec6.0.0SPECIAL TESTS 6.1.0EMC Immunity (IEC 60255-22; 22-1; 22-2; 22-3; 22-4) (IEC 60255-22;22-1;22-2;22-3;22-4)YesYes6.2.0EMC Emission (IEC 60255-22, IEC 61000-4, IEEE / ANSI C37.90) (IEC 60255-22,IEC 61000-4,IEEE / ANSI c37.90)YesYes6.3.0Insulation (IEC 255-5) (IEC 255-5)YesYes6.4.0Mechanical Efforts IEC255-21, IEC68-2 iec255-21,iec68-2YesYes6.5.0Environmental Testing IEC60068, IEC68-2 iec60068,iec68-2YesYes7.0.0PROTECTION FUNCTIONS 7.1.0List of included functions Transformer Differential (87T) YesYesDistance between phases and ground phase (21 / 21N) (21/21 n)Do notNoPhase overcurrent and ground phase (50/51, 50 / 51N) YesYesDirectional phase and ground phase overcurrent (67 / 67N) YesYesMinimum and maximum voltage (27/59) (27 / 59)YesYesBay controller up to 30 devices (6 switches) 30(6)Do notDo notSwitch failure (50BF) (50bf)YesYesOverexcitation (24) (24)YesYesSynchronization check (25) (25)YesYesThermal Overload (49) (49)YesYesFrequency (81) (81)YesYesFault Recording and Oscillographs (RF / RO) YesYes7.2.0Transformer Differential (87T) (87t)- Operation characteristic -Adaptable Yes- Precision In± 2.0%, for I <Ir± 1.0% of Irr for I < Ir± 1.0% of I for I > Ir- Sensitive base function In10-60%(4.0-100.0)% of Ibase- Unrestricted differential current limit In100-500090-6000- Second Harmonica Restrictionfundamental5.0 - 100%- Fifth Harmonica Restriction fundamental5.0 - 100%- Connection type of each winding Y, star or D, DeltaY- Phase shifting between the High Dev W1 and each of the W2, and W3 windings notation 0 - 11Time - Operating time, restricted function Ms25, tIpeak of 0 to 2 x Id25 ms typically at 0 to 10 x IdMin7.3.0Phase and ground phase instantaneous overcurrent (50 / 50N) (50/50N)- Adjustment steps (minimum) 1- Operating current range %Ibase(1 to 2500)%Ibase- Operation time Ms25 ms (0 to 2Iset)10 ms (0 to 10Iset)- Replacement time Ms25 ms (0 to 2Iset)35 ms (0 to 10Iset)7.4.0Phase overcurrent phase (51/67) and ground phase (51N / 67N) (51 / 67)(51n / 67n)- Adjustment steps 4- Operating current range % In(1 to 2500)%Ibase(5-2500)% of lbase- Minimum operating current (1-100)%IbaseMeet- Characteristic angle of relay 51/67 Degrees-70 to -50Meet- Maximum forward angle Degrees40-70Meet- Minimum forward angle Degrees75 to 90Meet- Characteristic angle of the relay 51N / 67N Degrees-180 to 180Meet- Blocking per second harmonic%(5-100%) of the fundamentalMeet- Timing Sec0 to 600 to 60ANSI timing curves ANSIANSI (Extremely Inverse, Very Inverse, Normal Inverse, Moderately Inverse, Extremely Inverse of Long Time, Very Inverse of Long Time, Inverse of Long Time) ANSI(,,,,,,)MeetIEC Timing Curves IECIEC (Normal Inverse, Very Inverse, Inverse, Extremely Inverse, Extr. Inverse Long time Inverse Short Time, Inverse Long Time) IEC(,,,,.,)Meet- Operating time, start function -,Ms25 (from 0 to 2Iset)20 ms typically at 0 to 2 x Iset- Reset time, start function -,Ms25 (2 to 0Iset)35 ms typically at 2 to 0 x Iset7.5.0Minimum voltage (27) - Number of adjustment steps 2Meet- Low and high setting range for operating voltage %Ubase1 -100(1-100)% of Ubase- Setting range for absolute hysteresis %Ubase0 -1000 -100- Low and high setting range for internal lock level %Ubase1 -1001 -100- Timing SDefinite Time (0-60) sec (0.00 - 6000.00) sProgrammable Curves Yes- Operating time for start-up function Ms25, tIpeak 2 to 0x Uset30 ms typically at 2 to 0.5 x Uset- Reset time for start-up function Ms25, tIpeak from 0 to 2 xUset40 ms typically at 0.5 to 2 x Uset7.6.0Maximum voltage (59) and Maximum residual voltage YesYes- Number of adjustment steps -22- Low and high setting range for operating voltage -% U base1 - 200(1-200)% of Ubase- Setting range for absolute hysteresis %Ubase0 - 1000 - 100- Timing Definite Time (0-60) sec (0.00 - 6000.00) sProgrammable Curves Yes- Operating time for start-up function Ms25, tIpeak from 0 to 2 xUset30 ms typically at 0 to 2 x Uset- Reset time for start-up function Ms25, tIpeak 2 to 0 xUset40 ms typically at 2 to 0 x Uset7.7.0Switch failure (50BF) - Phase current adjustment range %(5-200)%Ibase(5-200)% of lbase- Residual current adjustment range %(2-200)%Ibase(2-200)% of lbase- Timers Sec0 to 60(0.000-60.000) s- Operating time for current detection (typical) ()Ms1035 ms typically- Reset time for current detection (maximum) ()Msfifteen10 ms maximum7.8.0Overexcitation (24) (24)- Operating setting range for start up Ubase/ fn(100-180)%(100-180)% of (Ubase/frated)- Setting range of operation for alarm Ubase(0-100)%(50-120)% of start level- Operating setting range for high level -Ubase/ fn(100-200)%(100-200)% of (Ubase/frated)- Alarm timing S(0.000 - 60.000)(0.000-60.000) s7.9.0Synchronization check (25) (25)YesYes- Bar angle offset and line degrees-180 to 180-180 to 180- Ubarra / Uline tension ratio %(0.40 - 5.00)% ofUbase(0.40 - 5.00)% ofUbase- Setting range of the line-to-line frequency difference limit Hz0.003 - 10.003 - 1- Range adjustment of the line angle difference limit bar-line degrees(5.0 to 90.0)(5.0 to 90.0)- Bar-line voltage difference limit adjustment range %(2.0 - 50.0)% ofUbase(2.0 - 50.0)% ofUbase- Output timing for synchronization S(0.000 - 60.000)(0.000 - 60.000)- High voltage limit setting range %(50-120)% ofUbase(50-120)% ofUbase7.10.0Thermal Overload (49) (49)- base Current Setting Range I base(30-250)%(30-250)% of Ibase- Alarm setting % I shot(50-99)%(50-99)% of heat content trip value- Operating current adjustment range I base(50-250)%(50-250)% of Ibase7.11.0Frequency (81) (81)- Number of steps 6Meet- Frequency Functions M INIMA Frequency about Frecuencia Derived from Frequency - Adjustment range -Hz(35.00 - 75.00)(35.00-75.00) HzConSTRUCTIVE ASPECTS Hz / s(-10,000 - 10.00) steps 0.01MeetFrequency Ms100MeetWeight S(0.000 - 60.000)300kgApproximate Dimensions (Height, Width, Depth) (,,)SYesMounting Yes7.12.0Operating temperature YesStorage temperature S0.05 - 1-40...+85ºCRelative Humidity Range S0.1 - 10<93%TENSION AND CURRENT ANALOGUE INPUTS S0.5 - 101A/5ANumber of analog inputs No.9610~20Voltage inputs No.40- Number of entries -Sample / cycle twenty- Rated voltage (Vn) (V)Hz5 - 300- Operating margin No.1008.0.0- Maximum permanent voltage 8.1.0- Maximum tension for 10 seconds Burden YesCurrent Inputs Yes8.2.0- Number of entries -- Rated current (In) (IN)Yes- Operating margin Yes8.3.0- Maximum permanent current - Maximum current for 1 sec. 1000Burden YesDEPARTURES AND BINARY ENTRIES No.96Programmable Trip and Signaling Outputs No.40- Number of contacts (minimum) -()Ms18.4.0- Maximum operating voltage -YES8.4.1- Test voltage at the open contact, for 1 min. -,1.- Permanent current carrying capacity -YesNo.DEscriptIONTIONUNID.VALUE REQUIREDVALUE OFFERED1GENERAL DATA 1.1Country of manufacture Sweden/China1.2Maker ABB/SAC1.3Model REC6501.4.Kind multifunction ng NGmultifunction1.5Internal processing unit Microprocessors Microprocessors1.6Installation height (m) ()10001.7Rule IEC 60255MeetIEC 61000MeetIEC 60297MeetENV 50204Meet1.8Working temperature range ° C-10 to +50-25...+55oC (continuous)1.9RH%90<93%, non-condensing1.1MountingHorizontalHorizontal 1.1Phases03 phases + earth31.1Dimensions and weight * WidthMm220 mm* DepthMm265.9 mm (6U)* HeightMm249.5 mm* WeightKg<10 kg (6U)1.1ConsumptionGOES35W1.1Digital programming ---YesYes1.2Modular architecture ---YesYes1.2Oscillographs ---YesYes1.2Sensitivity MA1Meet1.2Degree of protectionIP52Front side:IP40Rear side, connection terminals:IP20Front and side:IP421.2Test voltage at 60Hz (1min)KV2Meet1.2Immunity to electrical and electromagnetic interference ---YesYes1.2Special Tests EMC Immunity IEC 255-22; 22-1; 22-2; 22-3; 22-4)---YesYesEMC Emission EN50081-2; EN55011 class A---YesYesInsulation (IEC 255-5) (IEC 255-5)---YesYesMechanical Efforts IEC255-21 IEC68-2---YesYes2NOMINAL DATA Frequency Hz6050/60HzRated current TO1 and 51A/5AChange of CT signal polarity via software CT---YesYesNominal voltage (between phases) autorang ()autorangVca100 to 120± 15%100,110,120,220,240 V ACMaximum permanent voltage Vca2Vn420 V rmsMaximum voltage for 1 minute 1Vca3.5Vn420 V(10s) rmsOverload capacity for current circuit (ms) 4 x In continuous 100 x In for 1secAuxiliary voltage, autorang ,autorangVcc110-250± 20%88...300 V DC3PROTECTION FUNCTIONS 3.1AVAILABILITY OF PROTECTION * Neutral Isolated *YesYes*Neutral Grounded Rigorously YesYes* Neutral Artificial using a ZIG-ZAG transformer ZIG-ZAGYesYes3.2PROTECTION CLOSURE ON FAILURE Dead Line Detection Voltage Range V(1 to 100)%Vn(1 to 100)%VnDead Line Detection Current Range TO(1 to 100)% In(1 to 100)% InEnablement time Msg<200<2003.3TIMER OVERLOADING (51 / 51N)Number of stages for function 51No.Mínimo 24Number of stages for function 51N No.Mínimo 24Setting current range % In10 to 2500MeetInverse Characteristic Curves, defined ,---IEC, ANSI and User DefinedIEC, ANSI3.4INSTANTANEOUS OVERLOADING (50 / 50N)Number of stages for function 50No.Mínimo 24Number of stages for the 50N functionNo.Mínimo 24Setting current range% In10 to 4000MeetDelay time rangeSeconds0.02 to 15Meet3.5DIRECTIonAL OVERCURRENT (67 / 67N) (67 / 67n)Number of stages for function 67No.Mínimo 24Number of stages for function 67NNo.Mínimo 24Polarization by zero / negative sequence---SpecifyPolarization angleºSpecifySetting current range% In10 to 3000MeetInverse Characteristic Curves, defined---IEC, ANSI and User DefinedIEC, ANSI3.6TENSION PROTECTION (59/27) Number of stepsNo.Mínimo 359:2 steps;27:2stepsMaximum voltage range%Vn80 to 150MeetMinimum voltage range%Vn10 to 100MeetDelay time rangeSeconds0 to 600 to 603.7PROTECTION FAULT SWITCH Operating CurrentTO(5-500)% In(5-500)% InDelay Time TriggerSeconds0 to 600 to 60Current detection for operating timemsec. <10Meet3.8OTHER PROTECTIONS AND FUNCTIONS Negative Sequence (46) (46)---YesYesTrip Circuit Supervision ---Mínimo 22Monitoring of the current circuit ---YesYesVoltage circuit supervision ---YesYesSwitch Condition Monitoring ---YesYesNumber of adjustment groups ---444ConTROL 4.1AUTOMATIC RECEPTION Number of steps No.Mínimo 55Criteria for initiation ---Configurable ConfigurableBlocking / Inhibition Criteria /---ConfigurableConfigurableDead time setting Seconds0.20 to 1000.20 to 100(Steps of 0.01 s)0.01sSynchronism check capability at recloser ---YESYesDiscrimination time Seconds0 to 10.000 to 10.00(Steps of 0.01)(Steps of 0.01)4.2SINCROCHECKAngle Range°(-180 to 180)(-180 to 180)Bar-line voltage limit rangeV(0.5-5.0)%Vn(0.5-5.0)%VnFrequency difference limit rangeHz(0.003-1.000)(0.003-1.000)Angle difference limit range°(5-90)(5-90)Voltage difference limit rangeV(2-50)%Vn(2-50)%VnFunction evaluation timeSeconds(0.0- 60.0)0~60sFunction operation timeMsg200Meet4.3EQUIPMENT ConTROL FUNCTIONS Control and control via the LCD display with position indication LCDNo.Mínimo: 2 switches, 3 disconnectors8Status indication of non-controllable equipment No.Specify According to the requirement.Local / remote front button /---YesYesAlternative selection of Local / Remote via binary input /---YESYesAutomation and Control Buttons No.Mínimo 5According to the requirement.5PLC ConFIGURATION AND PROGRAMMING ---YesYesProgramming via matrix logic ---YESYesProgramming through block diagram (graph) ()---YESYes6AUXILIARY ConTACTS 6.1OUTPUT Shooting ContactsNumber of contacts (minimum)No.Referring to Fig.According to the requirement.Operating VoltageYou125± 20%MeetPermanent IntensityTOReferring to Fig.MeetIntensity 3 secTOfifteenMeetIntensity at 0.5 secTO30MeetProgrammable output contacts---YESYesNumber of contacts (minimum)No.Referring to Fig.According to the requirement.Operating VoltageYou125± 20%MeetPermanent IntensityTO5MeetIntensity 3 secTO10MeetIntensity at 0.5 secTOfifteenMeet6.2INPUT Programmable Input Contacts---YESYesNumber of input contacts (minimum)No.2. 3According to the requirement.Voltage rangeYou24-25024-2507MonITORING AND REGISTRATION 7.1MEASUREMENTS Instantaneous values ---YesYesVoltages, currents, frequency, power and power factor ,,,---YESYesPrimary and secondary voltages and currents (phase and angle) ()---YESYesPositive, negative and zero sequence currents and voltages ,---YESYesActive and reactive power ---YESYesReal-time monitoring of measurement parameters ---YesYesVoltage signal input for calculation of measurement parameters ---YesYesStatus of controlled equipment (open, closed, undefined) (,,)---YESYes7.2OSCILOGRAPHY RECORDERNumber of binary signals No.64MeetNumber of physical analog signals No.30MeetNumber of analogue signals calculated No.10MeetSample Rate Sample / cl4,8,16,32or 64MeetBandwidth Cycles600600Pre-fault time Ms10 to 300010 to 3000Post-failure time Ms100 to 10000100 to 10000Number of registered oscillographs No.Mínimo 100MeetTotal recorder capacity Cycles1 Mbyte1 MbyteDrive by internal and external signals ---YesYesReal-time monitoring of relay inputs and outputs ---YesYesFile format COMTRADEYesIn case of power interruption, the events will be Stored in the volatile memory,YesYes7.3EVENT RECORDER Registered event numbers (available for extraction) ()No.10001000Stores sequentially, with date, time, second and millisecond indication ,,,---YESYes7.4FAULT RECORDER Number of records No.100100Pre-fault and current and voltage failure value---YESYes7.5TROUBLESHOOTING ---YESYes8LOCAL AND REMOTE COMMUNICATION 8.1Open communication protocol * IEC 61850---YesYesNative (no mappings or converters) ()---YesYesKEMA Certification KEMA---YesYesMessaging Goose YesDigital Signs ---YesYesAnalog Signals ---YesYesClass P1Kind A1Signal Transfer Speed Ms<2.5Meet* DNP 3.0 TCP / IP---YesNo* Modbus---Optional Optional8.2Ports of communication * RJ-45 Ethernet---YES, FrontYes* RJ-45 Ethernet---Yes, LaterYes* Ethernet Fiber Optic *---Yes, LaterYes* Stand-alone port for synchronization ---Yes, (IRIG B)IRIG-B9OPERATION INTERFACE 9.1LOCAL INTERFACE Front display and keypad ---YesYesInterface with control systems ---YesYesRemote communication ---YesYesInput and outputs for telemetering ---YesYesSelf-diagnosis or self-supervision ---YesYesPhase indication triggered ---YesYesSignal sending signal ---YesYesSignal reception ---YesYes9.2WEB-baseD INTERFACE WebEmbedded web server ---YesYesChanging Web Protection Settings ---YesYesDownload Oscillographs via web ---YesYesEvents Download Via web ---YesYesResetting of Indications and Alarms via web ---YesYesSecurity system ---YesYes10LED SIGNALING * Visual indicator ---YesYes* Minimum number of configurable LEDs No.Four. Five15* Shooting start ---YesYes* Shooting ---YesYes* Relay Status ---YesYes* Activated by external contact or internal function ---YesYes* Activation by protection function ---YesYes9SOFTWARE *Configuration software (with license) ---YesYes* Environment WindowsWindows 7* Security level (Password) ---YesYes* Download information ---YesYes* Oscillograph analysis software ---YesYes* Local programming ---YesYes* Remote programming ---YesYes* Relay communication cables - computer ---YesYes* Operation and configuration manual: :---Yesonly EnglishSpanish, English (original printed and in magnetic file pdf) ,(PDF)* Factory Certified Trainers ---YesYes* One Relay Simulator Module per person ---YesMeet* Assistants No.10According to the requirement.* Level Operator Duration days11* Duration Level Programmer days22* Factory Certification for attendees ---YesYes* Printed and digital documentation ---YesYesTECHNICAL DATA TABLE DIGITAL TYPE ALARM ANNOUNCER°DEscriptIONTIONUNID.VALUE REQUIREDVALUE OFFERED1Digital Alarm Announcer2For application in monitoring of alarms and signaling of Power Substations3QuantityUnd114SignalingDigital TypeYesYes5Identification of failures and alarms in formVisual and audible Visual6FeedingYouRange 18 to 80VdcMeet7Control voltage for identification circuits and alarm reset, obtaining from the power supply,YouMeetReferring to Fig. Internal You48Vdc +/- 20%.MeetReferring to Fig.Internal contact voltage48Vdc +/- 20%.Meet10Internal contact current: MA4mA +/- 20%.MeetelevenAlarm Channel Capacity :Und16 units.Min. 1612Activating channels using contacts NO (normally open)or NC (normally closed)NO13Reset Delay Times :5ms, 20 ms, 100 ms, 1 s, 5 s, 20 s, 60 s or 160 s.Meet14Manufacturing standard: IEC 660255-5, IEC 60255-6, IEC 60068-2-3IEC 660255-5, IEC 60255-6, IEC 60068-2-3MeetfifteenFor front panel mounting YesYes16Selection and configuration of parameters from front panel or via serial interface. .YesYes17Self-monitoring system that allows system availability and reliability .YesYes18Code ASCII transmission mode, 4800 or 9600 Bd transfe ASCII,48009600BDr.YesYes19Operating Temperature:° Cto 55° CMeettwentyDegree of protection: IP 54.IP 54Meettwenty-oneIncludes Equipment Manual and accessories for front panel mounting. .YesYesTABLE OF TECHNICAL DATA MULTIFUNCTION METER °DEscriptIONTIONUNID.VALUE REQUIREDVALUE OFFERED1MULTIFUNCTION METER 1MakerAlster1Team modelAC17001Operating Temperature: :-20° C - + 70-40ºC~+70ºC1Number of Threads:44 threads3-phase 3-wire,3-phase 4-wire1.1Rated currentTO1 to 55-6A, 5-10A, 1-2A, 1-1.2A1.1Voltage: AutorangoV (ln)57V to 347V57.5 - 240V (3 ph 4 wire)100 - 415V (3 ph 3 wire)1.1Power Supply 85-240Vac ± 10%70~265V AC/DC1.1FrequencyHz6050Hz or 60Hz1.1Class of Metrology IEC600687 0.2sor 02.S IEC62053-22IEC 62053 - 221.1Four Squaresyes1.1Information preservation without auxiliary power Minimum30 dies30Meet1.1Circular mass memoryMinimum60 diesMeet1.1Load Profile Option yesMeet1.1Number of Recording Channels, Minimum ,Referring to Fig.According to the requirement.1.2Number of Recording Channels, optimal ,6or 88 channels1.2Digital Inputs yesYes1.2Outputs for relays and control functionsyesYes1.2Analog I / O Option yesYes1.2Programming of any parameter or condition for control and alarm functions yesYes1.2Instant Instrumentation Values V, I, kW,kVAr, kVA, kWh, kVarh, frequency, FPV, I, kW,kVAr, kVA, kWh, kVarh, frequency, FP1.2Bidirectionality yesYes1.2Frozen readings option yesYes1.2Phasor diagram generation yesYes1.2External communication RS485, switchable with RS232 RS485RS232,yesYes1.3Communication protocol DNP 3.0 /Modbus Serial DNP3.O, Modbus and IEC 61850 thernetFlag IEC 62056-21 (formerly 61107)1.3Internal Modem Option yesYes1.3Event Logging and Handling yesYes1.3Power and Demand Channels yesYes1.3Redundant Font yesYes1.3RTC (Real Time Clock) RTC()Upgradable GPSRTC1.3POWER AND ENERGY DEMAND Voltage and current unbalance yesPls.refer to AC1700 manual.Frequency, power factor, apparent power, reactive and real power ,,,,yesYesExport and import of bidirectional energy yesYes1.3PQ ANALYSIS SAG / SWELL wave monitoring /yesPls.refer to AC1700 manual.Symmetrical components: Zero, Positive and Negative :,,yesPls.refer to AC1700 manual.Individual harmonics and total harmonic distortion greater than the 63rd 63yesPls.refer to AC1700 manual.Detection of transients greater than 17 us 17yesPls.refer to AC1700 manual.Sequence of Events yesPls.refer to AC1700 manual.Samples per cycle, above 1.0241024yesRegistry of Flicker and Harmonics of voltage according to NTCSE Peruana ntcseyesPls.refer to AC1700 manual.1.3DATA AND RECORDS OF WAVES Waveform recording of up to 214,000 continuous cycles with 16 samples per cycle. 214000,16.yesPls.refer to AC1700 manual.Point-driven: external signal and programs :yesPls.refer to AC1700 manual.Maximum / minimum records for any parameter /yesPls.refer to AC1700 manual.Historic records, maximum number of characters ,32Pls.refer to AC1700 manual.Resolution in seconds Samples per cycle, up to 1,024 ,1024yesPls.refer to AC1700 manual.Time Synchronization with GPS GPSyesPls.refer to AC1700 manual.1.3COMMON PORTS AND EXPANDABLE ENTRY / DEPARTURE /Ports RS-232/485 switchable RS-232/4851MeetRJ 45 port RJ 451MeetSlave Ports Modbus RTU Serial, Ethernet, Modem, I / R Modbus RTU,,,I/RyesYesPorts DNP 3.0, Modem and I / R DNP 3.0,I/RData transfer gateway modem / direct Ethernet network for RS-485 RS-485yesYesAnalog outputs with expandable input / output /4 inputs / 4 outputsPls.refer to AC1700 manual.Digital status, input counter ,Referring to Fig.Pls.refer to AC1700 manual.Digital relay outputs (control / pulse) (/)7 mínimoPls.refer to AC1700 manual.Sync port If (IRIG Bor NTP SERVER)Yes1.4.SEVEN POINTS FOR ConTROL AND ALARM Setting, mínimum response time 1sec or 1/2 cycle1secLinearization of mathematical, logical and logarithmic formulas ,yesYesSimple and multi - alarm alarms yesYesRemote Alarm Notification yesYes1.4.INCOME OF MEASUREMENTS Standards for accuracy: ANSI C12,60yesYesANSI standard C12,20 0.2yesYesStandard IEC 60687 0,2 SyesIEC 60687IEC 60687 standard, accuracy class 0,2 SyesYesLine Loss and Transformer Compensation yesYesMultiple annual scheduling, Hourly activity profiles ,yesYessoftware yesYes